Pendse, ChinmayChinmayPendseLykourinas, AntoniosAntoniosLykourinasPandit, Milind NarasimhaMilind NarasimhaPanditVan Hoof, ChrisChrisVan HoofRottenberg, XavierXavierRottenbergRochus, VeroniqueVeroniqueRochus2026-11-162026-11-162026979-8-3315-6250-22833-8553https://imec-publications.be/handle/20.500.12860/60828Sonomyography (SMG) is a promising alternative to surface electromyography (sEMG) for wearable human-machine interfaces. The first wearable PZT-based ultrasound armbands achieve up to 96% hand gesture recognition accuracy. To enhance compactness and acoustic compatibility, flexible piezoelectric micromachined ultrasound transducers (pMUTs) are being explored as replacements for rigid PZT elements. However, the acceptable requirements on operational parameters for optimal recognition performance remain unclear. This study simulates pMUT signals by filtering off-the-shelf PZT probe data and injecting noise to examine how frequency, bandwidth, and noise floor affect gesture recognition.engSimulating pMUT array characteristics for sonomyographic hand gesture recognitionProceedings paper10.1109/eurosime69483.2026.11511918WOS:001900864700037