Gyssels, LanderLanderGysselsDe Cock, CedricCedricDe CockLuchie, StijnStijnLuchieDe Poorter, EliEliDe PoorterTanghe, EmmericEmmericTanghePlets, DavidDavidPlets2026-09-082026-09-082025979-8-3315-5681-52162-7347https://imec-publications.be/handle/20.500.12860/60268This paper explores the use of a commercial-off-the-shelf impulse-radio ultra-wideband transceiver with 0.5 GHz bandwidth for ranging and respiration rate monitoring of a moving target. Respiration causes the chest to change in shape, which alters the target’s radar cross section, which causes periodical changes in the channel impulse response. A median filter, Viterbi algorithm and a particle filter are used to determine the range of the target, band-pass filtering and fourier transforming are used for respiration rate estimation. The results demonstrate that accurate localization and respiration rate monitoring is possible under controlled settings, but not in a realistic scenario.engJoint Ranging and Respiration Rate Monitoring for Moving Targets Using COTS IR-UWB HardwareProceedings paper10.1109/ipin66788.2025.11213365WOS:001828104600047TRAPPED VICTIMSRADAR