Publication:
Biofouling resistance of boron-doped diamond neural stimulation electrodes is superior to titanium nitride elctrodes in vivo
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.orcid | 0000-0003-0215-5033 | |
| cris.virtualsource.department | e7cacdac-f010-492e-846d-bce6f98e4f41 | |
| cris.virtualsource.orcid | e7cacdac-f010-492e-846d-bce6f98e4f41 | |
| dc.contributor.author | Meijs, S. | |
| dc.contributor.author | Alcaide, M. | |
| dc.contributor.author | Sorensen, C. | |
| dc.contributor.author | McDonald, Matthew | |
| dc.contributor.author | Sorensen, S. | |
| dc.contributor.author | Rechendorff, K. | |
| dc.contributor.author | Gerhardt, A. | |
| dc.contributor.author | Nesladek, Milos | |
| dc.contributor.author | Rijkhoff, N.J.M. | |
| dc.contributor.author | Pennisi, C.P. | |
| dc.contributor.imecauthor | Nesladek, Milos | |
| dc.date.accessioned | 2021-10-23T12:41:33Z | |
| dc.date.available | 2021-10-23T12:41:33Z | |
| dc.date.embargo | 9999-12-31 | |
| dc.date.issued | 2016 | |
| dc.identifier.doi | 10.1088/1741-2560/13/056011 | |
| dc.identifier.issn | 1741-2560 | |
| dc.identifier.uri | https://imec-publications.be/handle/20.500.12860/26988 | |
| dc.identifier.url | http://iopscience.iop.org/article/10.1088/1741-2560/13/5/056011/meta;jsessionid=2B03548DB80AFD3CCDA7AE7214080091.ip-10-40-1-87 | |
| dc.source.beginpage | 56011 | |
| dc.source.issue | 5 | |
| dc.source.journal | Journal of Neural Engineering | |
| dc.source.volume | 13 | |
| dc.title | Biofouling resistance of boron-doped diamond neural stimulation electrodes is superior to titanium nitride elctrodes in vivo | |
| dc.type | Journal article | |
| dspace.entity.type | Publication | |
| Files | Original bundle
| |
| Publication available in collections: |