Publication:

Simulating pMUT array characteristics for sonomyographic hand gesture recognition

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0003-0920-1709
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0001-9680-5724
cris.virtualsource.department48d3caed-8049-4a39-ae25-dd247b165b25
cris.virtualsource.department8cf83e05-1744-4c34-8fb6-9bb2a35a6992
cris.virtualsource.department48c5c9e1-8758-436d-bfb9-70a2f1fe3ada
cris.virtualsource.orcid48d3caed-8049-4a39-ae25-dd247b165b25
cris.virtualsource.orcid8cf83e05-1744-4c34-8fb6-9bb2a35a6992
cris.virtualsource.orcid48c5c9e1-8758-436d-bfb9-70a2f1fe3ada
dc.contributor.authorPendse, Chinmay
dc.contributor.authorLykourinas, Antonios
dc.contributor.authorPandit, Milind Narasimha
dc.contributor.authorVan Hoof, Chris
dc.contributor.authorRottenberg, Xavier
dc.contributor.authorRochus, Veronique
dc.date.accessioned2026-11-16T15:34:06Z
dc.date.available2026-11-16T15:34:06Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractSonomyography (SMG) is a promising alternative to surface electromyography (sEMG) for wearable human-machine interfaces. The first wearable PZT-based ultrasound armbands achieve up to 96% hand gesture recognition accuracy. To enhance compactness and acoustic compatibility, flexible piezoelectric micromachined ultrasound transducers (pMUTs) are being explored as replacements for rigid PZT elements. However, the acceptable requirements on operational parameters for optimal recognition performance remain unclear. This study simulates pMUT signals by filtering off-the-shelf PZT probe data and injecting noise to examine how frequency, bandwidth, and noise floor affect gesture recognition.
dc.identifier.doi10.1109/eurosime69483.2026.11511918
dc.identifier.isbn979-8-3315-6250-2
dc.identifier.issn2833-8553
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60828
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherIEEE
dc.relation.ispartofseriesInternational Conference on Thermal Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems
dc.source.beginpage1
dc.source.conference27th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE)
dc.source.conferencedate2026-04-19
dc.source.conferencelocationWarsaw
dc.source.endpage8
dc.source.journal2026 27TH INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS, EUROSIME
dc.source.numberofpages8
dc.title

Simulating pMUT array characteristics for sonomyographic hand gesture recognition

dc.typeProceedings paper
dspace.entity.typePublication
imec.internal.crawledAt2026-05-16
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-11-11
Files
Publication available in collections: