Publication:

Evaluation of a Dual Linear Flexible Ultrasound Array for Surgical Interventional Guidance

 
dc.contributor.authorRostamikhanghahi, Hasti
dc.contributor.authorIngram, Marcus
dc.contributor.authorBooth, Brian
dc.contributor.authorD'Hooge, Jan
dc.contributor.imecauthorBooth, Brian G.
dc.date.accessioned2025-05-10T05:36:13Z
dc.date.available2025-05-10T05:36:13Z
dc.date.issued2025
dc.description.abstractScaphoid fractures, the most common of wrist bone fractures, are typically treated using Percutaneous Scaphoid Fixation (PSF). Incorporating ultrasound guidance into this technique could reduce reliance on fluoroscopy, thereby avoiding ionizing radiation and improving procedural accuracy. However, the scaphoid’s position can shift as a result of hand movement during PSF, adding complexity to the procedure. Real-time ultrasound motion tracking of the scaphoid during PSF could simplify the intervention, which would necessitate a flexible transducer array to maintain contact during wrist motion. Our previous research proposed a transducer design with two parallel flexible 1D arrays, enabling simultaneous acquisition of two parallel images. This study focuses on transitioning from theoretical design to practical application by evaluating the performance of the custom array in terms of image quality using phantoms. We assessed image quality using the generalized contrast-to-noise ratio (gCNR) on a cyst phantom and the full width at half maximum (FWHM) on a wire phantom. Results demonstrated gCNR values above 0.67 and FWHM values below 0.70 mm across all sequences. These measurements fall within the acceptable range for the phantoms. Since the primary goal of the array is to track the scaphoid bone during surgery, requiring relatively high image quality, the values observed in this study are suitable for this application.
dc.description.wosFundingTextThis work was supported by the Fonds Wetenschappelijk Onderzoek (FWO) under the "HoloWrist"Project under Grant G0A8721N.
dc.identifier.doi10.1109/OJUFFC.2025.3560938
dc.identifier.issn2694-0884
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/45619
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
dc.source.beginpage43
dc.source.endpage47
dc.source.journalIEEE OPEN JOURNAL OF ULTRASONICS, FERROELECTRICS, AND FREQUENCY CONTROL
dc.source.numberofpages5
dc.source.volume5
dc.title

Evaluation of a Dual Linear Flexible Ultrasound Array for Surgical Interventional Guidance

dc.typeJournal article
dspace.entity.typePublication
Files

Original bundle

Name:
Evaluation_of_a_Dual_Linear_Flexible_Ultrasound_Array_for_Surgical_Interventional_Guidance.pdf
Size:
1.66 MB
Format:
Adobe Portable Document Format
Description:
Published
Publication available in collections: