Publication:

Single-shot phase-contrast computed tomography for multi-material samples

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0001-6256-9356
cris.virtualsource.department481d5519-e646-4bc2-89b0-180cc3233621
cris.virtualsource.department4f09de68-bd34-4ae5-bb52-1ff438565c1b
cris.virtualsource.orcid481d5519-e646-4bc2-89b0-180cc3233621
cris.virtualsource.orcid4f09de68-bd34-4ae5-bb52-1ff438565c1b
dc.contributor.authorMazzolani, Andrea
dc.contributor.authorAstolfo, Alberto
dc.contributor.authorDuncalf, Alexander
dc.contributor.authorDidziokas, Marius
dc.contributor.authorPauws, Erwin
dc.contributor.authorMoazen, Mehran
dc.contributor.authorFrancken, Nicholas
dc.contributor.authorVerstraete, Jitse
dc.contributor.authorModregger, Peter
dc.contributor.authorMunro, Peter R. T.
dc.contributor.authorOlivo, Alessandro
dc.date.accessioned2026-11-02T15:37:59Z
dc.date.available2026-11-02T15:37:59Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractEdge illumination (EI) is a mask-based X-ray phase-contrast imaging (XPCI) technique that converts small refraction-induced beam deviations into measurable intensity changes, enabling laboratory-compatible imaging with sensitivity beyond conventional absorption contrast. However, quantitative EI computed tomography typically requires multiple exposures per projection and computationally demanding iterative reconstruction, increasing acquisition time and radiation dose. Here, we present a single-shot technique for quantitative EI phase-contrast CT of multi-material samples based on a linear joint reconstruction (LJR) approach. The method uses a single exposure per angle of projection and directly reconstructs the sample’s absorption and phase components simultaneously. This is achieved by applying a first-order Taylor expansion to the system’s illumination curve, which linearizes the EI imaging model and transforms it into a convex least-squares problem with a unique semi-analytical solution, eliminating the non-convexity that typically leads to local minima in iterative approaches. As a result, the approach is both fast and robust. We demonstrate the method’s performance on both simulated and experimental datasets, including multi-material plastic rods and an intact mouse brain inside its native skull. The results show that the proposed technique produces high-quality, quantitatively accurate phase and absorption tomograms that are a close match to those obtained with the standard EI method while considerably reducing data acquisition and computational time. This development enables rapid, reliable XPCI of complex multi-material samples under challenging imaging conditions.
dc.description.wosFundingTextEngineering and Physical Sciences Research Council (EP/X018377/1, EP/W008092/1, EP/R513143/1-2592407, EP/T517793/1-2592407); Royal Academy of Engineering (CiET1819/2/78); Research Foundation-Flanders (S003421N).
dc.identifier.doi10.1364/optica.575949
dc.identifier.issn2334-2536
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60699
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherOptica Publishing Group
dc.source.beginpage1436
dc.source.endpage1446
dc.source.issue8
dc.source.journalOPTICA
dc.source.numberofpages11
dc.source.volume13
dc.subject.keywordsRAY
dc.subject.keywordsRETRIEVAL
dc.subject.keywordsIMAGE
dc.subject.keywordsCT
dc.title

Single-shot phase-contrast computed tomography for multi-material samples

dc.typeJournal article
dspace.entity.typePublication
imec.internal.crawledAt2026-09-07
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-09-07
Files

Original bundle

Name:
optica-13-8-1436.pdf
Size:
2.39 MB
Format:
Adobe Portable Document Format
Description:
Published
Publication available in collections: