Publication:

The Feasibility of Semi-Continuous and Multi-Frequency Thoracic Bioimpedance Measurements by a Wearable Device during Fluid Changes in Hemodialysis Patients

Date

 
dc.contributor.authorSchoutteten, Melanie K.
dc.contributor.authorLindeboom, Lucas
dc.contributor.authorDe Canniere, Helene
dc.contributor.authorPieters, Zoe
dc.contributor.authorBruckers, Liesbeth
dc.contributor.authorBrys, Astrid D. H.
dc.contributor.authorvan der Heijden, Patrick
dc.contributor.authorDe Moor, Bart
dc.contributor.authorPeeters, Jacques
dc.contributor.authorVan Hoof, Chris
dc.contributor.authorGroenendaal, Willemijn
dc.contributor.authorKooman, Jeroen P.
dc.contributor.authorVandervoort, Pieter M.
dc.contributor.imecauthorVan Hoof, Chris
dc.contributor.orcidimecVan Hoof, Chris::0000-0002-4645-3326
dc.date.accessioned2024-05-13T13:16:31Z
dc.date.available2024-04-04T18:34:36Z
dc.date.available2024-05-13T13:16:31Z
dc.date.embargo2024-03-15
dc.date.issued2024
dc.description.wosFundingTextThe authors are indebted to Seppe Lambeets, Sander Driesen, Hanne Jeurissen, Lennert Snijkers, and Michiel De Wever for their invaluable help in the collection of the patient data. We would like to thank the clinical and technical staff at the participating dialysis units for their help and support, and the engineers from imec the Netherlands for their technical support. This research is part of the Limburg Clinical Research Center (LCRC) UHasselt-ZOL-Jessa, supported by the foundation Limburg Sterk Merk (LSM), province of Limburg, Flemish government, UHasselt, Ziekenhuis Oost-Limburg, and Jessa Hospital, Belgium.
dc.identifier.doi10.3390/s24061890
dc.identifier.issn1424-8220
dc.identifier.pmidMEDLINE:38544153
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/43772
dc.publisherMDPI
dc.source.beginpageArt. 1890
dc.source.endpageN/A
dc.source.issue6
dc.source.journalSENSORS
dc.source.numberofpages22
dc.source.volume24
dc.subject.keywordsBIOELECTRICAL-IMPEDANCE ANALYSIS
dc.subject.keywordsBLOOD-VOLUME
dc.subject.keywordsBODY-FLUID
dc.subject.keywordsEXTRACELLULAR WATER
dc.subject.keywordsSHIFTS
dc.subject.keywordsCOMPARTMENTS
dc.subject.keywordsINTRA
dc.title

The Feasibility of Semi-Continuous and Multi-Frequency Thoracic Bioimpedance Measurements by a Wearable Device during Fluid Changes in Hemodialysis Patients

dc.typeJournal article
dspace.entity.typePublication
Files

Original bundle

Name:
sensors-24-01890.pdf
Size:
4.49 MB
Format:
Adobe Portable Document Format
Description:
Published version
Publication available in collections: