Publication:

Investigation of low-frequency noise in Cryogenic CMOS devices through statistical single-defect spectroscopy

Date

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0009-0007-8427-9318
cris.virtual.orcid0000-0001-7127-6184
cris.virtual.orcid0000-0002-0402-8225
cris.virtual.orcid0000-0002-4609-5573
cris.virtual.orcid0000-0002-8186-071X
cris.virtual.orcid0000-0002-1314-9715
cris.virtual.orcid0000-0003-1615-1033
cris.virtual.orcid0000-0001-6121-0069
cris.virtual.orcid0000-0002-1484-4007
cris.virtual.orcid0000-0001-5018-4539
cris.virtual.orcid0000-0002-1120-5197
cris.virtualsource.department56ec315a-bc87-4cd9-9780-c53663438329
cris.virtualsource.departmentf18a94c5-dec4-4d3b-9c24-72e56f0471a2
cris.virtualsource.departmentf2e648b4-91e6-42de-bb5d-66326414095e
cris.virtualsource.department8b84673b-878f-4c3b-959d-b7cdae2d70d9
cris.virtualsource.department0328af28-0868-452b-9c77-facda8733c82
cris.virtualsource.department4f080abc-66ee-4e68-8205-c00721990942
cris.virtualsource.departmentf5422aad-241b-410a-a7b7-28bf124c06e0
cris.virtualsource.department89a91aff-dba9-4deb-bc4c-d5206f2f4e17
cris.virtualsource.department812f2909-a81b-4593-9b32-75331cffa35c
cris.virtualsource.department81d20142-643b-4ea2-8f89-390fd699ef91
cris.virtualsource.department5c84eae4-a73c-478e-b3aa-854fe071efa7
cris.virtualsource.orcid56ec315a-bc87-4cd9-9780-c53663438329
cris.virtualsource.orcidf18a94c5-dec4-4d3b-9c24-72e56f0471a2
cris.virtualsource.orcidf2e648b4-91e6-42de-bb5d-66326414095e
cris.virtualsource.orcid8b84673b-878f-4c3b-959d-b7cdae2d70d9
cris.virtualsource.orcid0328af28-0868-452b-9c77-facda8733c82
cris.virtualsource.orcid4f080abc-66ee-4e68-8205-c00721990942
cris.virtualsource.orcidf5422aad-241b-410a-a7b7-28bf124c06e0
cris.virtualsource.orcid89a91aff-dba9-4deb-bc4c-d5206f2f4e17
cris.virtualsource.orcid812f2909-a81b-4593-9b32-75331cffa35c
cris.virtualsource.orcid81d20142-643b-4ea2-8f89-390fd699ef91
cris.virtualsource.orcid5c84eae4-a73c-478e-b3aa-854fe071efa7
dc.contributor.authorCatapano, Edoardo
dc.contributor.authorVaranasi, Anirudh
dc.contributor.authorRoussel, Philippe
dc.contributor.authorDegraeve, Robin
dc.contributor.authorHigashi, Yusuke
dc.contributor.authorAsanovski, Ruben
dc.contributor.authorKaczer, Ben
dc.contributor.authorDiaz Fortuny, Javier
dc.contributor.authorWaltl, M.
dc.contributor.authorAfanasiev, Valeri
dc.contributor.authorDe Greve, Kristiaan
dc.contributor.authorGrill, Alexander
dc.date.accessioned2026-10-28T13:37:44Z
dc.date.available2026-10-28T13:37:44Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractHigh 1/๐‘“ noise in Cryogenic CMOS (CryoCMOS) devices is a critical parameter to keep under control in the design of complex circuits for low-temperature applications. Current models predict the 1/๐‘“ noise to scale linearly with temperature, and gate oxide defects are expected to freeze out at cryogenic temperatures. Nevertheless, it has been repeatedly observed that 1/๐‘“ noise deviates from the predicted behavior and that gate oxide defects are still active around 4.2 K, producing random telegraph noise. In this paper, we probe single-gate oxide defects in 2500 nMOS devices down to 5 K in order to investigate the origin of 1/๐‘“ noise in CryoCMOS devices. From our results, it is clear that the number of defects active at cryogenic temperatures resulting in random telegraph noise is larger than at 300 K. Threshold voltage shifts due to charged defects are shown to be exponentially distributed, with different modalities across temperatures and biases: from monomodal at 300 K to trimodal below 100 K. Distributionsโ€™ shapes are interpreted in the framework of percolation theory. By fitting these distributions, it is shown that more than 80% of the detected defects belong to the bulk oxide. Afterward, starting from the raw data in the time domain, we reconstruct the low-frequency noise spectra, highlighting the contributions of defects belonging to different branches and, therefore, to different oxide layers. This analysis shows that, although interface traps and large defects associated with the third mode are the main sources of 1/๐‘“ noise at 5 K, bulk oxide defects still contribute significantly to low-frequency noise at cryogenic temperatures. Finally, we show that defect time constants and step heights are uncorrelated, proving that the elastic tunneling model for charge trapping is not accurate.
dc.description.wosFundingTextThis work is funded in part by imec's Industrial Affiliation Program on Quantum Computing and Cryoelectronics.
dc.identifier.doi10.1103/zcnb-xpwj
dc.identifier.issn2331-7019
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60627
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherAMER PHYSICAL SOC
dc.source.beginpage044022
dc.source.issue4
dc.source.journalPHYSICAL REVIEW APPLIED
dc.source.numberofpages14
dc.source.volume26
dc.subject.keywordsRANDOM TELEGRAPH NOISE
dc.subject.keywordsCENTRIC PERSPECTIVE
dc.subject.keywordsVARIABILITY
dc.subject.keywordsTEMPERATURES
dc.subject.keywordsORIGIN
dc.subject.keywordsMOSFET
dc.subject.keywordsFDSOI
dc.subject.keywordsBTI
dc.title

Investigation of low-frequency noise in Cryogenic CMOS devices through statistical single-defect spectroscopy

dc.typeJournal article
dspace.entity.typePublication
imec.internal.crawledAt2026-10-24
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-10-24
Files
Publication available in collections: