Publication:
A 300-Channel Photometry Neural Probe with In-Pixel Adaptive-Noise ΔΣ Modulators Achieving 16.8 fA/√Hz Noise for High-Sensitivity Fluorescence Recording
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.orcid | 0000-0003-4200-0001 | |
| cris.virtual.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.orcid | 0000-0002-0620-0033 | |
| cris.virtual.orcid | 0000-0001-9900-528X | |
| cris.virtual.orcid | 0000-0001-6486-5132 | |
| cris.virtualsource.department | 061aa94e-9a35-494d-a68e-50b157d00dd3 | |
| cris.virtualsource.department | 29bfa967-3bf8-4818-9526-30a59762502d | |
| cris.virtualsource.department | 52c7ccb8-4fc8-437c-a738-76761b8056e9 | |
| cris.virtualsource.department | a76786e4-4d8d-43ef-9c97-3605ed22cb05 | |
| cris.virtualsource.department | 7dfabec6-85cc-4ffa-9ded-a87faf398eb8 | |
| cris.virtualsource.orcid | 061aa94e-9a35-494d-a68e-50b157d00dd3 | |
| cris.virtualsource.orcid | 29bfa967-3bf8-4818-9526-30a59762502d | |
| cris.virtualsource.orcid | 52c7ccb8-4fc8-437c-a738-76761b8056e9 | |
| cris.virtualsource.orcid | a76786e4-4d8d-43ef-9c97-3605ed22cb05 | |
| cris.virtualsource.orcid | 7dfabec6-85cc-4ffa-9ded-a87faf398eb8 | |
| dc.contributor.author | Li, Mengyu | |
| dc.contributor.author | Yang, Xiaolin | |
| dc.contributor.author | Rodriguez, Alejandro Lopez | |
| dc.contributor.author | Duckert, Bastien | |
| dc.contributor.author | Neutens, Pieter | |
| dc.contributor.author | Jaramillo, Valentina Restrepo | |
| dc.contributor.author | Coppejans, Phillippe | |
| dc.contributor.author | Mora Lopez, Carolina | |
| dc.date.accessioned | 2026-11-23T10:09:12Z | |
| dc.date.available | 2026-11-23T10:09:12Z | |
| dc.date.createdwos | 2026 | |
| dc.date.issued | 2026 | |
| dc.description.abstract | This work presents a 300 -channel photometry neural probe with in-pixel readout for scalable, high-resolution fluorescence sensing. Each channel integrates an on-chip photodiode and a ΔΣ-based adaptive-noise readout with serialized data transfer. By exploiting a duty-cycled unipolar current DAC (IDAC) with a passive integrator, the readout achieves an adaptive noise floor with a compact implementation. The input-referred noise decreases at lower signal levels, enabling an 88.7 dB dynamic range which is 12 dB higher than the peak SNR. The system achieves an ultra-low noise floor of 16.8fA/√Hz while consuming 70 nW per channel. Each channel occupies 0.0015 mm2 with a 25μ m pitch, supporting high-spatialresolution neural recording along the probe shank. | |
| dc.identifier.doi | 10.1109/vlsitechnologyandcir65830.2026.11577415 | |
| dc.identifier.eissn | 2158-9682 | |
| dc.identifier.isbn | 979-8-3315-8097-1 | |
| dc.identifier.issn | 0743-1562 | |
| dc.identifier.uri | https://imec-publications.be/handle/20.500.12860/60898 | |
| dc.language.iso | eng | |
| dc.provenance.editstepuser | greet.vanhoof@imec.be | |
| dc.publisher | IEEE | |
| dc.relation.ispartofseries | Symposium on VLSI Technology | |
| dc.source.beginpage | 1 | |
| dc.source.conference | IEEE/JSAP Symposium on VLSI Technology and Circuits | |
| dc.source.conferencedate | 2026-06-14 | |
| dc.source.conferencelocation | Honolulu | |
| dc.source.endpage | 3 | |
| dc.source.journal | 2026 IEEE/JSAP SYMPOSIUM ON VLSI TECHNOLOGY AND CIRCUITS, VLSI TECHNOLOGY AND CIRCUITS | |
| dc.source.numberofpages | 3 | |
| dc.title | A 300-Channel Photometry Neural Probe with In-Pixel Adaptive-Noise ΔΣ Modulators Achieving 16.8 fA/√Hz Noise for High-Sensitivity Fluorescence Recording | |
| dc.type | Proceedings paper | |
| dspace.entity.type | Publication | |
| imec.internal.crawledAt | 2026-07-04 | |
| imec.internal.source | crawler | |
| imec.internal.wosCreatedAt | 2026-11-22 | |
| Files | ||
| Publication available in collections: |