Publication:

Improved IOL Power CalculationWith Femtosecond Laser Enhanced Refractive Outcome Prediction

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-9620-888X
cris.virtual.orcid0000-0002-7865-6793
cris.virtual.orcid0000-0001-9531-0623
cris.virtual.orcid0000-0001-7124-692X
cris.virtualsource.department05fb97f7-814f-45c5-a574-69ac02eecc3c
cris.virtualsource.department43fd6f27-126a-4a10-8c2e-2c15e86e4898
cris.virtualsource.department76cf4419-0a17-432e-8eb2-5050faec6ce4
cris.virtualsource.department27de9bdb-933c-45ba-b02b-60ba3775db06
cris.virtualsource.orcid05fb97f7-814f-45c5-a574-69ac02eecc3c
cris.virtualsource.orcid43fd6f27-126a-4a10-8c2e-2c15e86e4898
cris.virtualsource.orcid76cf4419-0a17-432e-8eb2-5050faec6ce4
cris.virtualsource.orcid27de9bdb-933c-45ba-b02b-60ba3775db06
dc.contributor.authorVan Der Donckt, Jeroen
dc.contributor.authorYoung, Joshua A.
dc.contributor.authorRademaker, Michael
dc.contributor.authorMenon, Saurabh
dc.contributor.authorChang, Chin-Wen
dc.contributor.authorVandewiele, Gilles
dc.contributor.authorStraker, Benjamin
dc.contributor.authorDewey, David
dc.contributor.authorDai, George
dc.contributor.authorGonzalez, Javier
dc.contributor.authorFree, Joseph R.
dc.contributor.authorVan Hoecke, Sofie
dc.contributor.authorScott, Wendell
dc.contributor.authorTauber, Shachar
dc.contributor.authorDick, H. Burkhard
dc.contributor.authorScales, Charles
dc.date.accessioned2026-05-04T09:32:10Z
dc.date.available2026-05-04T09:32:10Z
dc.date.createdwos2026-03-24
dc.date.issued2025
dc.description.abstractPurpose: The purpose of this study was to introduce and evaluate the femtosecond laser enhanced refractive outcome (FLERO) prediction method, an intraocular lens (IOL) calculator that augments Barrett Universal II (BUII) by integrating novel anterior segment optical coherence tomography (OCT) biometric predictors obtained during femtosecond laser-assisted cataract surgery (FLACS). Methods: Two thousand, three hundred sixty-three (2363) eyes of 1720 patients (mean age = 71.33 years, 60.26% women) undergoing FLACS were analyzed. FLERO was developed by selecting the most predictive subset of OCT-derived biometry features using a “genetic algorithm” and combining them with BUII predictions in a linear model. Internal validation was performed through cross-validation, and prediction errors (PEs) were compared with BUII and Kane errors. Results: Compared to BUII, FLERO increased the proportion of eyes achieving postoperative refraction within ±0.25 diopter (D), ±0.50 D, and ±1.00 D of target from 0.470 to 0.507, 0.781 to 0.824, and 0.962 to 0.970, respectively. Mean absolute error decreased from 0.345 D for BUII and 0.338 D for Kane to 0.315 D for FLERO. FLERO outperformed BUII and Kane across (short, medium, and long) eyes, where proportions of eyes achieving refraction within ±0.50 D were 0.696, 0.831, and 0.782 for FLERO, 0.468, 0.796, and 0.718 for BUII, and 0.595, 0.798, and 0.718 for Kane. Wilcoxon Signed-Rank testing indicated significant reductions in absolute PEs for FLERO versus BUII and Kane (P < 0.0001). PE regression revealed FLERO made significantly smaller errors. Conclusions: FLERO enhances BUII by incorporating novel OCT-derived FLACS biometric parameters across short, medium, and long eyes.
dc.description.wosFundingTextSupported by Johnson & Johnson, with locations in Jacksonville, Florida andMilpitas, California, USA. The sponsor participated in the design of the study, conducting the study, data collection, data management, data analysis, interpretation of the data, and preparation, review, and approval of the manuscript.
dc.identifier.doi10.1167/tvst.14.11.15
dc.identifier.issn2164-2591
dc.identifier.pmidMEDLINE:41235860
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/59283
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherASSOC RESEARCH VISION OPHTHALMOLOGY INC
dc.source.beginpage15
dc.source.issue11
dc.source.journalTRANSLATIONAL VISION SCIENCE & TECHNOLOGY
dc.source.numberofpages12
dc.source.volume14
dc.subject.keywordsINTRAOCULAR-LENS POWER
dc.subject.keywordsCALCULATION FORMULAS
dc.subject.keywordsARTIFICIAL-INTELLIGENCE
dc.subject.keywordsACCURACY
dc.subject.keywordsEYES
dc.title

Improved IOL Power CalculationWith Femtosecond Laser Enhanced Refractive Outcome Prediction

dc.typeJournal article
dspace.entity.typePublication
imec.internal.crawledAt2025-11-20
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-04-07
Files

Original bundle

Name:
i2164-2591-14-11-15_1763044965.96191.pdf
Size:
508.02 KB
Format:
Adobe Portable Document Format
Description:
Published
Publication available in collections: