Publication:

Automated calibration of model-driven reconstructions in atom probe tomography

 
dc.contributor.authorFletcher, Charles
dc.contributor.authorMoody, Michael P.
dc.contributor.authorFleischmann, Claudia
dc.contributor.authorDialameh, Masoud
dc.contributor.authorPorret, Clément
dc.contributor.authorGeiser, Brian
dc.contributor.authorHaley, Daniel
dc.contributor.imecauthorFleischmann, Claudia
dc.contributor.imecauthorDialameh, Masoud
dc.contributor.imecauthorPorret, Clément
dc.contributor.orcidimecFleischmann, Claudia::0000-0003-1531-6916
dc.contributor.orcidimecDialameh, Masoud::0000-0002-1439-590X
dc.contributor.orcidimecPorret, Clément::0000-0002-4561-348X
dc.date.accessioned2023-01-04T11:23:20Z
dc.date.available2022-07-09T02:28:04Z
dc.date.available2023-01-04T11:23:20Z
dc.date.issued2022
dc.description.wosFundingTextCharles Fletcher acknowledges support from CAMECA (R) for financially supporting this research. Charles Fletcher and Michael P Moody acknowledge support from the EPSRC Impact Acceleration Account Award EP/R511742/1. Michael P Moody and Daniel Haley acknowledge support from the ESPRC Project Advanced Nuclear Materials EP/P001645/1. The imec core program members, local authorities, and the imec pilot line are acknowledged for their support. The authors acknowledge the financial support by FWO-Hercules through Projects ZW13_09 and AKUL/15/22. The authors would like to thank Hugo Bender, Paromita Kundu and Olivier Richard (imec Belgium) for performing the electron microscopy in this work, and Masoud Dialameh, Davit Melkonyan and Jeroen E Scheerder (imec Belgium), for obtaining the experimental APT datasets. The authors' would also like to thank Ian Griffiths from the Mathematical Institute, University of Oxford, for his help with considering the continuity of the trajectory mapping (for which further details can be found in [15]), and for insightful discussion.
dc.identifier.doi10.1088/1361-6463/ac7986
dc.identifier.issn0022-3727
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/40101
dc.publisherIOP Publishing Ltd
dc.source.beginpage375301
dc.source.endpagena
dc.source.issue37
dc.source.journalJOURNAL OF PHYSICS D-APPLIED PHYSICS
dc.source.numberofpages20
dc.source.volume55
dc.subject.keywordsLEVEL SET APPROACH
dc.subject.keywordsLOCAL MAGNIFICATION
dc.subject.keywordsPROJECTION
dc.subject.keywordsGEOMETRY
dc.title

Automated calibration of model-driven reconstructions in atom probe tomography

dc.typeJournal article
dspace.entity.typePublication
Files

Original bundle

Name:
Fletcher_2022_J._Phys._D__Appl._Phys._55_375301.pdf
Size:
11.67 MB
Format:
Adobe Portable Document Format
Description:
Published version
Publication available in collections: