Publication:

Mesh modeling of system geometry and anatomy phantoms for realistic GATE simulations and their inclusion in SPECT reconstruction

 
dc.contributor.authorAuer, Benjamin
dc.contributor.authorKonik, Arda
dc.contributor.authorFromme, Timothy J.
dc.contributor.authorDe Beenhouwer, Jan
dc.contributor.authorKalluri, Kesava S.
dc.contributor.authorLindsay, Clifford
dc.contributor.authorFurenlid, Lars R.
dc.contributor.authorKuo, Philip H.
dc.contributor.authorKing, Michael A.
dc.contributor.imecauthorDe Beenhouwer, Jan
dc.contributor.orcidimecDe Beenhouwer, Jan::0000-0001-5253-1274
dc.date.accessioned2023-07-17T09:43:00Z
dc.date.available2023-04-29T04:11:35Z
dc.date.available2023-07-17T09:43:00Z
dc.date.issued2023
dc.description.wosFundingTextResearch reported herein was supported by the National Institute of Biomedical Imaging and Bioengineering of the National Institutes of Health under Award Number R01 EB022521. The contents are the sole responsibility of the authors and do not necessarily represent the official views of the National Institutes of Health. An initial report of ideas was presented at the 2018 IEEE Nuclear Science Symposium and Medical Imaging Conference (Auer et al 2018b). The authors disclose that Dr Phillip H. Kuo has a financial interest in and partial employment at Invicro, a Konica Minolta company. He is also a consultant and/or speaker for Amgen, Eisai, General Electric Healthcare, Novartis, Invicro, Bayer, Chimerix, Fusion Pharma, and UroToday. He is a recipient of research grants from Blue Earth Diagnostics and General Electric Healthcare. We would like to warmly thank Dr Paul Segars for allowing us to distribute free of charge to the community a version of the STL-based phantom introduced in this work (https://github.com/BenAuer2021/Mesh-based-Human-Phantom-for-Simulation).
dc.identifier.doi10.1088/1361-6560/acbde2
dc.identifier.issn0031-9155
dc.identifier.pmidMEDLINE:36808915
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/41505
dc.publisherIOP Publishing Ltd
dc.source.beginpageArt. 075015
dc.source.endpagena
dc.source.issue7
dc.source.journalPHYSICS IN MEDICINE AND BIOLOGY
dc.source.numberofpages22
dc.source.volume68
dc.subject.keywordsMONTE-CARLO SIMULATIONS
dc.subject.keywordsBRAIN
dc.subject.keywordsIMPLEMENTATION
dc.subject.keywordsRADIOTHERAPY
dc.subject.keywordsDESIGN
dc.title

Mesh modeling of system geometry and anatomy phantoms for realistic GATE simulations and their inclusion in SPECT reconstruction

dc.typeJournal article
dspace.entity.typePublication
Files
Publication available in collections: