Publication:

A 6.78 MHz wirelessly powered sensing system for the long-term monitoring of the GI tract

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0009-0009-6954-2725
cris.virtual.orcid0000-0002-5668-7644
cris.virtual.orcid0000-0002-1302-3346
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-3852-2379
cris.virtualsource.departmentef83945f-6e7b-4210-8f84-6b7b581d1665
cris.virtualsource.departmente689906e-86e2-422e-8b9b-2afce44881de
cris.virtualsource.department57e85479-0a90-4281-b019-97f60eb073dc
cris.virtualsource.department52b0c342-ef98-4073-9202-f7c3bc841d41
cris.virtualsource.department7c263d8e-ef86-45b0-b0df-a1e346c9c397
cris.virtualsource.department45c66425-18a1-4e09-bf3b-1e7f54e8ff8b
cris.virtualsource.orcidef83945f-6e7b-4210-8f84-6b7b581d1665
cris.virtualsource.orcide689906e-86e2-422e-8b9b-2afce44881de
cris.virtualsource.orcid57e85479-0a90-4281-b019-97f60eb073dc
cris.virtualsource.orcid52b0c342-ef98-4073-9202-f7c3bc841d41
cris.virtualsource.orcid7c263d8e-ef86-45b0-b0df-a1e346c9c397
cris.virtualsource.orcid45c66425-18a1-4e09-bf3b-1e7f54e8ff8b
dc.contributor.authorRammouz, Ramzy
dc.contributor.authorStanzione, Stefano
dc.contributor.authorVis, Peter
dc.contributor.authorAdamopoulos, Vasileios
dc.contributor.authorCastro Miller, Ivan Dario
dc.contributor.authorGarripoli, Carmine
dc.contributor.authorTorfs, Tom
dc.contributor.orcidext0000-0002-5668-7644
dc.date.accessioned2026-07-23T10:33:35Z
dc.date.available2026-07-23T10:33:35Z
dc.date.createdwos2026
dc.date.issued2025
dc.description.abstractThis article presents a battery-free system with a 6.78 MHz wireless power transfer (WPT) link for the long-term monitoring of the gastrointestinal tract. For this purpose, a 2.7x2.7mm2 Application Specific Integrated Circuit (ASIC) is developed and validated. It enables efficient power reception at microwatt power levels deep in the human body. The ASIC is interfaced to ultra-low power electronics that measure and wirelessly transmit data from ten sensor readouts suitable for use in ingestible sensing capsules. The system’s ability to operate at a depth of 8 cm within human tissue while adhering to Specific Absorption Rate limits is demonstrated in an experimental setup.
dc.description.wosFundingTextThis work is supported in part by the European Commission through the Horizon 2020 Program, under GA AUTOCAPSULE (contract nr. 952118).
dc.identifier.doi10.1109/biocas67066.2025.00085
dc.identifier.isbn979-8-3315-7337-9
dc.identifier.issn2163-4025
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/59927
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherIEEE COMPUTER SOC
dc.relation.ispartofseriesBiomedical Circuits and Systems Conference
dc.source.beginpage364
dc.source.conferenceIEEE Biomedical Circuits and Systems Conference (BioCAS)
dc.source.conferencedate2025-10-16
dc.source.conferencelocationAbu Dhabi
dc.source.endpage368
dc.source.journal2025 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE, BIOCAS
dc.source.numberofpages5
dc.subject.keywordsCAPSULE
dc.subject.keywordsRECTIFIER
dc.subject.keywordsSENSOR
dc.subject.keywordsRANGE
dc.title

A 6.78 MHz wirelessly powered sensing system for the long-term monitoring of the GI tract

dc.typeProceedings paper
dspace.entity.typePublication
imec.internal.crawledAt2026-04-07
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-07-14
Files
Publication available in collections: