Publication:

Joint Ranging and Respiration Rate Monitoring for Moving Targets Using COTS IR-UWB Hardware

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-8879-5076
cris.virtual.orcid0000-0002-2738-0854
cris.virtual.orcid0000-0003-0020-6466
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-2724-6989
cris.virtual.orcid0000-0002-0214-5751
cris.virtualsource.departmente7f09615-933f-45d6-a4f4-aa904299fc08
cris.virtualsource.departmentc6f42aff-b1ea-4db2-a14a-b0b463a1fef5
cris.virtualsource.department79248d32-9470-424f-82b9-55f4ffa70920
cris.virtualsource.department1a592bc4-e1d6-46c0-9f07-f0597dc7159c
cris.virtualsource.departmentb9806ced-e002-467b-ad08-5739c33d2f6a
cris.virtualsource.departmenteb7ed649-7114-4ead-84d3-05a804e8fb45
cris.virtualsource.orcide7f09615-933f-45d6-a4f4-aa904299fc08
cris.virtualsource.orcidc6f42aff-b1ea-4db2-a14a-b0b463a1fef5
cris.virtualsource.orcid79248d32-9470-424f-82b9-55f4ffa70920
cris.virtualsource.orcid1a592bc4-e1d6-46c0-9f07-f0597dc7159c
cris.virtualsource.orcidb9806ced-e002-467b-ad08-5739c33d2f6a
cris.virtualsource.orcideb7ed649-7114-4ead-84d3-05a804e8fb45
dc.contributor.authorGyssels, Lander
dc.contributor.authorDe Cock, Cedric
dc.contributor.authorLuchie, Stijn
dc.contributor.authorDe Poorter, Eli
dc.contributor.authorTanghe, Emmeric
dc.contributor.authorPlets, David
dc.date.accessioned2026-09-08T10:06:19Z
dc.date.available2026-09-08T10:06:19Z
dc.date.createdwos2026
dc.date.issued2025
dc.description.abstractThis paper explores the use of a commercial-off-the-shelf impulse-radio ultra-wideband transceiver with 0.5 GHz bandwidth for ranging and respiration rate monitoring of a moving target. Respiration causes the chest to change in shape, which alters the target’s radar cross section, which causes periodical changes in the channel impulse response. A median filter, Viterbi algorithm and a particle filter are used to determine the range of the target, band-pass filtering and fourier transforming are used for respiration rate estimation. The results demonstrate that accurate localization and respiration rate monitoring is possible under controlled settings, but not in a realistic scenario.
dc.identifier.doi10.1109/ipin66788.2025.11213365
dc.identifier.isbn979-8-3315-5681-5
dc.identifier.issn2162-7347
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60268
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherIEEE
dc.relation.ispartofseriesInternational Conference on Indoor Positioning and Indoor Navigation
dc.source.beginpage1
dc.source.conferenceInternational Conference on Indoor Positioning and Indoor Navigation (IPIN)
dc.source.conferencedate2025-09-15
dc.source.conferencelocationTampere
dc.source.endpage7
dc.source.journal2025 INTERNATIONAL CONFERENCE ON INDOOR POSITIONING AND INDOOR NAVIGATION, IPIN
dc.source.numberofpages7
dc.subject.keywordsTRAPPED VICTIMS
dc.subject.keywordsRADAR
dc.title

Joint Ranging and Respiration Rate Monitoring for Moving Targets Using COTS IR-UWB Hardware

dc.typeProceedings paper
dspace.entity.typePublication
imec.internal.crawledAt2025-10-22
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-09-07
Files
Publication available in collections: