Publication:

A single-layer compton camera for nuclear decommissioning: An improved back-projection algorithm

Date

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-4019-5979
cris.virtualsource.department73187a2f-4799-45d3-9ae1-7cd599fe36b8
cris.virtualsource.orcid73187a2f-4799-45d3-9ae1-7cd599fe36b8
dc.contributor.authorSimons, Mattias
dc.contributor.authorMichiels, Anouk
dc.contributor.authorGenoe, Jan
dc.contributor.authorSchroeyers, Wouter
dc.contributor.imecauthorGenoe, Jan
dc.contributor.orcidimecGenoe, Jan::0000-0002-4019-5979
dc.date.accessioned2025-03-04T19:59:49Z
dc.date.available2025-03-04T19:59:49Z
dc.date.issued2025-MAR
dc.description.wosFundingTextThis work was also supported by the Fund for Scientific Research Flanders [Fonds Wetenschappelijk Onderzoek (FWO) ] scholarship nr 1SA2621N and 1SA2623N hosted by UHasselt.The computational resources and services used in this work were provided by the VSC (Flemish Supercomputer Center) , funded by the Research Foundation-Flanders (FWO) and the Flemish Government.This research was performed in the context of the ARCHER sproject. The archer project was carried out by academic research partners UHasselt and KU Leuven in collaboration with the industrial partners EQUANS and Magics Instruments. This project is funded by the Energy Transition Fund of the FOD economy (federal government Belgium) . The publication exclusively contains the opinions of the authors. The General Directorate Energy is not liable for any use of the information in the current paper.During the preparation of this work, the author (s) used ChatGPT to improve the readability of the introduction and methods section. After using this tool/service, the author (s) reviewed and edited the content as needed and take (s) full responsibility for the publication's content
dc.identifier.doi10.1016/j.net.2024.09.027
dc.identifier.issn1738-5733
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/45292
dc.publisherKOREAN NUCLEAR SOC
dc.source.beginpage103224
dc.source.issue3
dc.source.journalNUCLEAR ENGINEERING AND TECHNOLOGY
dc.source.numberofpages12
dc.source.volume57
dc.subject.keywordsRECONSTRUCTION
dc.subject.keywordsRESOLUTION
dc.title

A single-layer compton camera for nuclear decommissioning: An improved back-projection algorithm

dc.typeJournal article
dspace.entity.typePublication
Files

Original bundle

Name:
1-s2.0-S173857332400473X-main.pdf
Size:
5.44 MB
Format:
Adobe Portable Document Format
Description:
Published
Publication available in collections: