Publication:

Experimental and analytical characterisation of hybrid timber-glass diaphragms with integrated photovoltaics

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0001-7653-3979
cris.virtual.orcid0000-0002-9221-4932
cris.virtualsource.departmentbcf6c89c-dae5-4e6f-8926-d8e95e19d338
cris.virtualsource.department6135dbc2-f1c6-4a89-ab31-0608a53994c6
cris.virtualsource.orcidbcf6c89c-dae5-4e6f-8926-d8e95e19d338
cris.virtualsource.orcid6135dbc2-f1c6-4a89-ab31-0608a53994c6
dc.contributor.authorEngelen, Tine
dc.contributor.authorByloos, Dries
dc.contributor.authorHenriques, Jose
dc.contributor.authorDaenen, Michaël
dc.contributor.authorKozlowski, Marcin
dc.contributor.authorVandoren, Bram
dc.date.accessioned2026-02-02T13:43:55Z
dc.date.available2026-02-02T13:43:55Z
dc.date.createdwos2025-11-17
dc.date.issued2025
dc.description.abstractThis study investigates the structural performance of hybrid timber-glass frame walls designed to enhance racking resistance in façades, with a specific focus on the integration of photovoltaic solar cells within structural glass elements. The effects of shear loads on the system’s components and the applicability of analytical design methods are evaluated. To achieve this, eight diaphragms (1.2 × 1.2 m) were tested under in-plane shear loading using two different structural silicone adhesives, with or without a tie-down anchoring of the leading stud. A variety of measurement techniques, including displacement sensors (LVDTs), digital image correlation, fibre Bragg gratings and strain gauges were simultaneously employed to analyse the behaviour of the different components. The specimens primarily failed due to adhesive rupture. It is shown that adding wall anchorage increases the system’s racking stiffness by 30%. This study offers insights into the strains measured on the glass and solar cells during mechanical in-plane shear load tests. Furthermore, an analytical design method based on the relevant Eurocode (prEN 1995-1-1) and spring models is proposed and compared with the experimental results. The findings reveal that while this method tends to underestimate the stiffness of the wall elements, it provides an accurate prediction of the minimum load-bearing capacity.
dc.identifier.doi10.1016/j.engstruct.2025.121058
dc.identifier.issn0141-0296
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/58763
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherELSEVIER SCI LTD
dc.source.beginpage121058
dc.source.issue15 November
dc.source.journalENGINEERING STRUCTURES
dc.source.numberofpages14
dc.source.volume343
dc.subject.keywordsADHESIVE
dc.subject.keywordsELEMENTS
dc.subject.keywordsCONNECTIONS
dc.subject.keywordsRESISTANCE
dc.subject.keywordsBEHAVIOR
dc.title

Experimental and analytical characterisation of hybrid timber-glass diaphragms with integrated photovoltaics

dc.typeJournal article
dspace.entity.typePublication
imec.internal.crawledAt2025-11-20
imec.internal.sourcecrawler
Files
Publication available in collections: