Publication:

Optimizing Multilevel Microvia Structures for Thermo-mechanical Reliability in High-speed HDI PCBs

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-6413-998X
cris.virtual.orcid0000-0002-1867-827X
cris.virtualsource.departmenta72f374b-1b54-4114-9ce4-22b3601c10e5
cris.virtualsource.department8aa0c758-c770-49d7-bfd4-e80498e6e40b
cris.virtualsource.orcida72f374b-1b54-4114-9ce4-22b3601c10e5
cris.virtualsource.orcid8aa0c758-c770-49d7-bfd4-e80498e6e40b
dc.contributor.authorNawghane, Chinmay
dc.contributor.authorCauwe, Maarten
dc.contributor.authorVan De Slyeke, Marnix
dc.contributor.authorHeltzel, Stan
dc.date.accessioned2026-11-16T15:34:02Z
dc.date.available2026-11-16T15:34:02Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractHigh-Density Interconnect (HDI) printed circuit boards (PCBs) rely on stacked and staggered microvias to achieve compact, high-performance interconnects. However, the thermo-mechanical reliability of these microvias remains a critical concern due to cyclic stresses induced by mismatched coefficients of thermal expansion (CTE) between copper and dielectric materials. This study investigates the strain behavior of multilevel microvia configurations using finite element analysis (FEA) under reflow thermal cycling from 20 °C to 230 °C. A unit-cell modeling approach is employed to simulate various microvia offsets relative to a core via, ranging from fully stacked to fully staggered arrangements. Results reveal that partially overlapped microvias particularly those offset by ±100 μm exhibit the highest strain concentrations, exceeding those in fully stacked configurations. These key offsets occur when microvias with a top diameter of 150 μm and a bottom diameter of 100 μm partially overlap, causing increased stress at their interface. These findings highlight the detrimental impact of misregistration-induced partial overlaps and underscore the importance of avoiding overlap in staggered designs. Ongoing thermal cycling experiments on HDI test coupons are being conducted to validate the simulation results through cross-sectional failure analysis. The study provides actionable insights for optimizing microvia placement to enhance the reliability of HDI PCBs in high-performance applications.
dc.description.wosFundingTextThis work has been performed in the frame of the ESA GSTP-funded HSHDI project (ESA contract no. 4000141676/23/NL/AR). The authors gratefully acknowledge the support of the European Space Agency and all project partners for their contributions and collaboration throughout the study.
dc.identifier.doi10.1109/eurosime69483.2026.11511984
dc.identifier.isbn979-8-3315-6250-2
dc.identifier.issn2833-8553
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60827
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherIEEE
dc.relation.ispartofseriesInternational Conference on Thermal Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems
dc.source.beginpage1
dc.source.conference27th International Conference on Thermal, Mechanical and Multi-Physics Simulation and Experiments in Microelectronics and Microsystems (EuroSimE)
dc.source.conferencedate2026-04-19
dc.source.conferencelocationWarsaw
dc.source.endpage7
dc.source.journal2026 27TH INTERNATIONAL CONFERENCE ON THERMAL, MECHANICAL AND MULTI-PHYSICS SIMULATION AND EXPERIMENTS IN MICROELECTRONICS AND MICROSYSTEMS, EUROSIME
dc.source.numberofpages7
dc.title

Optimizing Multilevel Microvia Structures for Thermo-mechanical Reliability in High-speed HDI PCBs

dc.typeProceedings paper
dspace.entity.typePublication
imec.internal.crawledAt2026-05-16
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-11-11
Files
Publication available in collections: