Publication:

Real-Time On-Chip Time-of-Flight Detection for US Time Reversal Localization of Implants

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-4645-3326
cris.virtual.orcid0000-0003-2207-6260
cris.virtual.orcid0000-0002-7511-1923
cris.virtual.orcid0000-0002-0544-9646
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0009-0003-2152-6749
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtualsource.department167f3fe9-5a33-4143-92b1-a1c815093eba
cris.virtualsource.department2fc8d3eb-f814-4a6c-bef3-4ea4c9d4519e
cris.virtualsource.department6189ca6a-2d02-40c7-8e16-8babd37e9c27
cris.virtualsource.departmentd92971fe-fe87-455f-8582-782d7dd4587b
cris.virtualsource.department47159c5f-0ffc-4566-abd0-142bd0ea25f1
cris.virtualsource.department056b7d52-cf9d-4357-bb58-2ebd4c782800
cris.virtualsource.department7c263d8e-ef86-45b0-b0df-a1e346c9c397
cris.virtualsource.orcid167f3fe9-5a33-4143-92b1-a1c815093eba
cris.virtualsource.orcid2fc8d3eb-f814-4a6c-bef3-4ea4c9d4519e
cris.virtualsource.orcid6189ca6a-2d02-40c7-8e16-8babd37e9c27
cris.virtualsource.orcidd92971fe-fe87-455f-8582-782d7dd4587b
cris.virtualsource.orcid47159c5f-0ffc-4566-abd0-142bd0ea25f1
cris.virtualsource.orcid056b7d52-cf9d-4357-bb58-2ebd4c782800
cris.virtualsource.orcid7c263d8e-ef86-45b0-b0df-a1e346c9c397
dc.contributor.authorParag, Anirudh Kumar
dc.contributor.authorRaducanu, Bogdan
dc.contributor.authorStanzione, Stefano
dc.contributor.authorHendrickx, Patrick
dc.contributor.authorErden, Oguz Kaan
dc.contributor.authorVan Hoof, Chris
dc.contributor.authorVan Helleputte, Nick
dc.contributor.authorGielen, George
dc.date.accessioned2026-11-05T15:34:47Z
dc.date.available2026-11-05T15:34:47Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractTime-reversal (TR) localization using ultrasound (US) has emerged as a promising method to localize mm-sized deep-tissue implantable medical devices (IMDs) without requiring precise prior positional knowledge. While in-vitro studies using commercial off-the-shelf (COTS) systems have validated its efficacy, practical deployment demands significant system miniaturization to enable low-power, wearable implementations. To this end, this paper presents a proof-of-concept ASIC architecture comprising 45 channels, each featuring an integrated receive and transmit chain. A key component is a novel peak-instance-detection (PID) circuit that detects the time of flight (ToF) of incoming US signals in real time via dynamic thresholding and that simultaneously digitizes the result, eliminating the need to store full waveforms. This enables TR with minimal power and memory overhead. The ASIC is implemented in the TSMC 130-nm BCD+ technology. Electrical measurements confirm accurate ToF detection from recorded US backscatter signals. The PID reduces the per-channel receive power to 100 μW – achieving a 2000X reduction over COTS alternatives. Memory usage is also minimized, requiring only 540 bits to store ToFs across all channels – 746X lower than COTS approaches. Furthermore, the on-chip ToF digitization simplifies the TR computation, reducing it to a digital subtraction operation, in contrast to the complex convolutions typically employed. Finally, in-vitro experiments in heterogeneous scattering media using a 3D-printed human rib phantom demonstrate a 22X power efficiency improvement over unfocused US transmission, while matching the localization performance of MATLAB-based COTS implementations. These results highlight the feasibility of the proposed architecture as a miniaturized platform for TR-based IMD localization.
dc.identifier.doi10.1109/tbcas.2026.3665787
dc.identifier.eissn1940-9990
dc.identifier.issn1932-4545
dc.identifier.pmidMEDLINE:41701594
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60755
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherIEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
dc.source.beginpage589
dc.source.endpage602
dc.source.issue4
dc.source.journalIEEE TRANSACTIONS ON BIOMEDICAL CIRCUITS AND SYSTEMS
dc.source.numberofpages14
dc.source.volume20
dc.subject.keywordsCMOS
dc.title

Real-Time On-Chip Time-of-Flight Detection for US Time Reversal Localization of Implants

dc.typeJournal article
dspace.entity.typePublication
imec.internal.crawledAt2026-02-18
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-09-07
Files
Publication available in collections: