Publication:

Inline Edge Illumination Computed Tomography: A Simulation Study

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0001-5253-1274
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0001-6256-9356
cris.virtual.orcid0000-0003-4225-2487
cris.virtualsource.department57462492-22a3-4a15-844a-371bf8a18da3
cris.virtualsource.department481d5519-e646-4bc2-89b0-180cc3233621
cris.virtualsource.department4f09de68-bd34-4ae5-bb52-1ff438565c1b
cris.virtualsource.department33ee4c5e-70fd-4640-9a4b-6dff3f3210d0
cris.virtualsource.orcid57462492-22a3-4a15-844a-371bf8a18da3
cris.virtualsource.orcid481d5519-e646-4bc2-89b0-180cc3233621
cris.virtualsource.orcid4f09de68-bd34-4ae5-bb52-1ff438565c1b
cris.virtualsource.orcid33ee4c5e-70fd-4640-9a4b-6dff3f3210d0
dc.contributor.authorVerstraete, Jitse
dc.contributor.authorFrancken, Nicholas
dc.contributor.authorSijbers, Jan
dc.contributor.authorDe Beenhouwer, Jan
dc.date.accessioned2026-11-10T09:34:58Z
dc.date.available2026-11-10T09:34:58Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractDue to the growing demand for inspection in the context of Industry 4.0, non-destructive testing is predominantly performed inline by irradiating a sample and measuring the intensity loss caused by X-ray attenuation. This results in a 2D attenuation-based projection image. Combining multiple projection images taken at different angular views, allows the creation of a 3D reconstruction of the sample. With dedicated setups, additional contrasts can also be recovered, such as phase contrast. Combining phase-sensitive X-ray techniques with full 3D reconstructions has the potential to significantly enhance the information gained during inspection. A 2D inline acquisition method has previously been demonstrated using a modified edge illumination phase contrast setup, allowing the retrieval of both attenuation and phase contrast by measuring an illumination curve. Extending this approach to 3D, however, remains a challenge, requiring a novel acquisition scheme that integrates sample translation, rotation and illumination curve sampling. In this paper, we propose a flexible inline edge illumination CT method that facilitates this extension without hardware modifications, while offering freedom in parameters, such as the number of projection angles and illumination curve points. Through a realistic simulation study, we show that the proposed method can be applied for inline inspection without increasing the number of required projections compared to conventional edge illumination X-ray imaging.
dc.description.wosFundingTextThis work was funded by the Research Foundation Flanders (FWO) project FoodPhase (S003421N) and UA IOF-POC project X4Food (FFI240371).
dc.identifier.doi10.1109/melecon64486.2026.11418832
dc.identifier.isbn979-8-3315-2685-6
dc.identifier.issn2158-8481
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60783
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherIEEE
dc.relation.ispartofseriesIEEE Mediterranean Electrotechnical Conference-MELECON
dc.source.beginpage1
dc.source.conferenceIEEE 23RD MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON
dc.source.conferencedate2026-02-26
dc.source.conferencelocationCairo
dc.source.endpage6
dc.source.journal2026 IEEE 23RD MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON
dc.source.numberofpages6
dc.title

Inline Edge Illumination Computed Tomography: A Simulation Study

dc.typeProceedings paper
dspace.entity.typePublication
imec.internal.crawledAt2026-04-07
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-09-07
Files
Publication available in collections: