Publication:
Inline Edge Illumination Computed Tomography: A Simulation Study
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.department | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.orcid | 0000-0001-5253-1274 | |
| cris.virtual.orcid | #PLACEHOLDER_PARENT_METADATA_VALUE# | |
| cris.virtual.orcid | 0000-0001-6256-9356 | |
| cris.virtual.orcid | 0000-0003-4225-2487 | |
| cris.virtualsource.department | 57462492-22a3-4a15-844a-371bf8a18da3 | |
| cris.virtualsource.department | 481d5519-e646-4bc2-89b0-180cc3233621 | |
| cris.virtualsource.department | 4f09de68-bd34-4ae5-bb52-1ff438565c1b | |
| cris.virtualsource.department | 33ee4c5e-70fd-4640-9a4b-6dff3f3210d0 | |
| cris.virtualsource.orcid | 57462492-22a3-4a15-844a-371bf8a18da3 | |
| cris.virtualsource.orcid | 481d5519-e646-4bc2-89b0-180cc3233621 | |
| cris.virtualsource.orcid | 4f09de68-bd34-4ae5-bb52-1ff438565c1b | |
| cris.virtualsource.orcid | 33ee4c5e-70fd-4640-9a4b-6dff3f3210d0 | |
| dc.contributor.author | Verstraete, Jitse | |
| dc.contributor.author | Francken, Nicholas | |
| dc.contributor.author | Sijbers, Jan | |
| dc.contributor.author | De Beenhouwer, Jan | |
| dc.date.accessioned | 2026-11-10T09:34:58Z | |
| dc.date.available | 2026-11-10T09:34:58Z | |
| dc.date.createdwos | 2026 | |
| dc.date.issued | 2026 | |
| dc.description.abstract | Due to the growing demand for inspection in the context of Industry 4.0, non-destructive testing is predominantly performed inline by irradiating a sample and measuring the intensity loss caused by X-ray attenuation. This results in a 2D attenuation-based projection image. Combining multiple projection images taken at different angular views, allows the creation of a 3D reconstruction of the sample. With dedicated setups, additional contrasts can also be recovered, such as phase contrast. Combining phase-sensitive X-ray techniques with full 3D reconstructions has the potential to significantly enhance the information gained during inspection. A 2D inline acquisition method has previously been demonstrated using a modified edge illumination phase contrast setup, allowing the retrieval of both attenuation and phase contrast by measuring an illumination curve. Extending this approach to 3D, however, remains a challenge, requiring a novel acquisition scheme that integrates sample translation, rotation and illumination curve sampling. In this paper, we propose a flexible inline edge illumination CT method that facilitates this extension without hardware modifications, while offering freedom in parameters, such as the number of projection angles and illumination curve points. Through a realistic simulation study, we show that the proposed method can be applied for inline inspection without increasing the number of required projections compared to conventional edge illumination X-ray imaging. | |
| dc.description.wosFundingText | This work was funded by the Research Foundation Flanders (FWO) project FoodPhase (S003421N) and UA IOF-POC project X4Food (FFI240371). | |
| dc.identifier.doi | 10.1109/melecon64486.2026.11418832 | |
| dc.identifier.isbn | 979-8-3315-2685-6 | |
| dc.identifier.issn | 2158-8481 | |
| dc.identifier.uri | https://imec-publications.be/handle/20.500.12860/60783 | |
| dc.language.iso | eng | |
| dc.provenance.editstepuser | greet.vanhoof@imec.be | |
| dc.publisher | IEEE | |
| dc.relation.ispartofseries | IEEE Mediterranean Electrotechnical Conference-MELECON | |
| dc.source.beginpage | 1 | |
| dc.source.conference | IEEE 23RD MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON | |
| dc.source.conferencedate | 2026-02-26 | |
| dc.source.conferencelocation | Cairo | |
| dc.source.endpage | 6 | |
| dc.source.journal | 2026 IEEE 23RD MEDITERRANEAN ELECTROTECHNICAL CONFERENCE, MELECON | |
| dc.source.numberofpages | 6 | |
| dc.title | Inline Edge Illumination Computed Tomography: A Simulation Study | |
| dc.type | Proceedings paper | |
| dspace.entity.type | Publication | |
| imec.internal.crawledAt | 2026-04-07 | |
| imec.internal.source | crawler | |
| imec.internal.wosCreatedAt | 2026-09-07 | |
| Files | ||
| Publication available in collections: |