Publication:

Twenty heads are better than one: scalable microAFM for highthroughput metrology and inspection

Date

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0002-6377-4199
cris.virtual.orcid0000-0002-7503-8922
cris.virtualsource.departmentfde8f386-0ddb-42e1-ad64-53cde7dda12d
cris.virtualsource.department9a3d60e7-3e8b-4366-b479-ea599b23d28b
cris.virtualsource.orcidfde8f386-0ddb-42e1-ad64-53cde7dda12d
cris.virtualsource.orcid9a3d60e7-3e8b-4366-b479-ea599b23d28b
dc.contributor.authorGabriel, Leo
dc.contributor.authorMarcano, Jorge
dc.contributor.authorHerz, Erik
dc.contributor.authorCao, Zhenle
dc.contributor.authorWang, Qianshu
dc.contributor.authorMoussa, Alain
dc.contributor.authorBogdanowicz, Janusz
dc.contributor.authorMorris, David
dc.date.accessioned2026-09-03T15:02:58Z
dc.date.available2026-09-03T15:02:58Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractWith the increasing complexity of semiconductor manufacturing, process windows shrink and higher resolution measurement is required. Most measurement techniques face a trade-off between resolution and throughput, but scalable approaches can overcome this trade-off to maintain productivity. Atomic force microscopy (AFM) is an essential technique for high-resolution measurement, and one way to overcome the throughput-resolution trade-off is by operating multiple AFMs in parallel. Here, we demonstrate scalable microAFM technology for semiconductor metrology and inspection. Each microAFM device is a full MEMS AFM scan head, containing integrated XYZ scanners and sensors in a 1 mm² footprint. We demonstrate a system with twenty parallel microAFM scan heads capable of collecting data from multiple points per die (within die variation) and multiple dies (within wafer/die-to-die variation) simultaneously on a 300-mm wafer. To evaluate the system, the recess depth of fine-pitch copper pads for hybrid bonding were measured. This work highlights a path toward scaling AFM to full-die and full-wafer metrology and inspection with microAFM.
dc.identifier.doi10.1117/12.3089715
dc.identifier.isbn978-1-5106-9908-3
dc.identifier.issn0277-786X
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60216
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherSPIE-INT SOC OPTICAL ENGINEERING
dc.source.beginpage139810T
dc.source.conferenceMetrology, Inspection, and Process Control XL
dc.source.conferencedate2022-02-22
dc.source.conferencelocationSan Jose
dc.source.journalMETROLOGY, INSPECTION, AND PROCESS CONTROL XL, PT 1
dc.source.numberofpages7
dc.title

Twenty heads are better than one: scalable microAFM for highthroughput metrology and inspection

dc.typeProceedings paper
dspace.entity.typePublication
imec.internal.crawledAt2026-07-14
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-07-14
Files
Publication available in collections: