Publication:

BSE Grey-Level-Based CD-SEM Metrology for Scumming Quantification of High-NA EUV Contact Holes

Date

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0003-3498-5082
cris.virtual.orcid0009-0008-6879-2178
cris.virtual.orcid0000-0003-4370-5062
cris.virtual.orcid0000-0003-4745-0167
cris.virtualsource.department0cddeaa4-4a9c-44ee-a5d6-ba4f3945e8a7
cris.virtualsource.department45b3c197-6661-4f60-a2ed-4a867012d28f
cris.virtualsource.department4a8b9964-4471-41ab-a0c3-215a0d1acfbc
cris.virtualsource.department264c186e-7bc4-4bed-8d4f-11fe1bff9e26
cris.virtualsource.orcid0cddeaa4-4a9c-44ee-a5d6-ba4f3945e8a7
cris.virtualsource.orcid45b3c197-6661-4f60-a2ed-4a867012d28f
cris.virtualsource.orcid4a8b9964-4471-41ab-a0c3-215a0d1acfbc
cris.virtualsource.orcid264c186e-7bc4-4bed-8d4f-11fe1bff9e26
dc.contributor.authorSun, Wei
dc.contributor.authorVan den Heuvel, Dieter
dc.contributor.authorSuh, Hyo Seon
dc.contributor.authorLorusso, Gian
dc.contributor.authorCharley, Anne-Laure
dc.contributor.authorIsawa, Miki
dc.contributor.authorMiura, Akihiro
dc.date.accessioned2026-11-05T14:18:34Z
dc.date.available2026-11-05T14:18:34Z
dc.date.createdwos2026
dc.date.issued2026
dc.description.abstractHigh-NA EUV lithography has begun patterning hexagonal contact holes (CHs) with a center-to-center (C2C) pitch of 28 nm, which are expected to be first used in D0a DRAM technology generation. This extremely tight pitch challenges photoresist performance and process control, directly affecting pattern quality and yield. While CD-SEM can measure the CD and its uniformity, quantifying residual photoresist at the CH bottom—known as scumming— remains challenging. Scumming can transfer through subsequent etching steps and potentially cause contact failure. To address this, we developed a BSE grey-level-based metrology using 300 eV landing energy to detect and quantify scumming in CHs without requiring prior modeling. The scumming number dependence on the exposure dose and focus were evaluated for chemically-amplified resists (CAR). Cross-section TEM analysis was performed to directly observe the scumming status, which showed good consistency with the top-view CD-SEM measurement results. Enabling CD and scumming to be measured from SE and BSE images acquired simultaneously, CD-SEM provides a more comprehensive and efficient method for resist screening and lithography‑process monitoring in High‑NA EUV patterning.
dc.identifier.doi10.1117/12.3089713
dc.identifier.eissn1996-756X
dc.identifier.isbn978-1-5106-9908-3
dc.identifier.issn0277-786X
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/60741
dc.language.isoeng
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherSPIE-INT SOC OPTICAL ENGINEERING
dc.relation.ispartofseriesProceedings of SPIE
dc.source.conferenceMETROLOGY, INSPECTION, AND PROCESS CONTROL XL
dc.source.conferencedate2026-02-22
dc.source.conferencelocationSan Jose
dc.source.journalMETROLOGY, INSPECTION, AND PROCESS CONTROL XL, PT 1
dc.source.numberofpages7
dc.title

BSE Grey-Level-Based CD-SEM Metrology for Scumming Quantification of High-NA EUV Contact Holes

dc.typeProceedings paper
dspace.entity.typePublication
imec.internal.crawledAt2026-07-14
imec.internal.sourcecrawler
imec.internal.wosCreatedAt2026-09-07
Files
Publication available in collections: