Publication:

Investigating the influence of individual physical effects on dimensional measurement deviations using XCT simulations

 
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.department#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0001-5253-1274
cris.virtual.orcid#PLACEHOLDER_PARENT_METADATA_VALUE#
cris.virtual.orcid0000-0003-4225-2487
cris.virtualsource.department57462492-22a3-4a15-844a-371bf8a18da3
cris.virtualsource.department19262694-6a74-4890-9720-0d33ed883ff6
cris.virtualsource.department33ee4c5e-70fd-4640-9a4b-6dff3f3210d0
cris.virtualsource.orcid57462492-22a3-4a15-844a-371bf8a18da3
cris.virtualsource.orcid19262694-6a74-4890-9720-0d33ed883ff6
cris.virtualsource.orcid33ee4c5e-70fd-4640-9a4b-6dff3f3210d0
dc.contributor.authorYosifov, Miroslav
dc.contributor.authorFernandes, Thiago Linhares
dc.contributor.authorZanini, Filippo
dc.contributor.authorCarmignato, Simone
dc.contributor.authorDe Beenhouwer, Jan
dc.contributor.authorSijbers, Jan
dc.contributor.authorKastner, Johann
dc.contributor.authorHeinzl, Christoph
dc.date.accessioned2026-03-26T11:18:47Z
dc.date.available2026-03-26T11:18:47Z
dc.date.issued2026
dc.description.abstractThis study investigates individual sources of measurement deviations associated with physical effects in X-ray computed tomography (XCT) imaging, including focal spot blur effect, detector modulation transfer function, Poisson-Gaussian noise, and virtual gain correction. Key parameters were modeled to reflect XCT device characteristics, such as X-ray tube properties as well as detector attributes. Using a calibrated object designed for XCT metrology, namely a hole plate, a series of experiments were conducted to reproduce real measurement setups in a virtual simulation environment. XCT scans are compared with simulated XCT data generated under various conditions, including different numbers of projections (120 and 1000) and with physical effects both enabled and disabled. Deviations for both real and simulated XCT were determined by measuring hole diameters and distances between cylinder holes and comparing these measurements to reference values from the calibrated object, allowing quantification of the impact of different physical effects on measurement accuracy. The analysis revealed that virtual gain correction and focal spot blur had the most significant impact on measurement accuracy, with deviations of 0.018 mm and 0.016 mm, while Poisson–Gaussian noise had a minor influence of about 0.008 mm. The simulation framework accurately replicates XCT behavior (SSIM = 0.9645 for a simulated 1000 projections) and isolates individual physical effects. This study provides insight into the relative contributions of different physical effects to measurement deviations in industrial XCT. The findings have shown potential to guide future efforts in improving measurement accuracy, estimating measurement uncertainty, and developing more realistic simulation tools for XCT metrology.
dc.identifier.doi10.1016/j.measurement.2025.120168
dc.identifier.issn0263-2241
dc.identifier.urihttps://imec-publications.be/handle/20.500.12860/58950
dc.language.isoen
dc.provenance.editstepusergreet.vanhoof@imec.be
dc.publisherElsevier
dc.relation.ispartofMEASUREMENT
dc.relation.ispartofseriesMEASUREMENT
dc.source.beginpage120168
dc.source.journalMeasurement
dc.source.numberofpages18
dc.source.volume263
dc.subjectRAY COMPUTED-TOMOGRAPHY
dc.subjectIMAGE QUALITY ASSESSMENT
dc.subjectMETROLOGY
dc.subjectACCURACY
dc.subjectUNCERTAINTY
dc.subjectX-ray computed tomography
dc.subjectDimensional measurement
dc.subjectUncertainty
dc.subjectXCT metrology
dc.subjectX-ray simulation
dc.subjectScience & Technology
dc.subjectTechnology
dc.title

Investigating the influence of individual physical effects on dimensional measurement deviations using XCT simulations

dc.typeJournal article
dspace.entity.typePublication
oaire.citation.editionWOS.SCI
oaire.citation.volume263
person.identifier.orcid0000-0002-6318-4869
person.identifier.orcid0000-0002-1230-586X
person.identifier.orcid0000-0002-4465-1230
person.identifier.orcid0000-0001-5253-1274
person.identifier.orcid0000-0003-4225-2487
person.identifier.orcid0000-0002-3173-8871
person.identifier.ridABA-2380-2021
person.identifier.rid#PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.rid#PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.ridA-5531-2012
person.identifier.rid#PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.rid#PLACEHOLDER_PARENT_METADATA_VALUE#
person.identifier.ridD-7272-2016
Files

Original bundle

Name:
1-s2.0-S0263224125035286-main.pdf
Size:
4.49 MB
Format:
Adobe Portable Document Format
Description:
Published
Publication available in collections: